Network Rack Size Guide: How Many U and Which Depth?

A network rack keeps your switches, patch panels, NVRs and servers secure, cool and organised. Choosing the right size comes down to three things: height in U, depth, and wall or floor mounting.

What Does "U" Mean?

U (rack unit) is the standard height measure: 1U = 1.75 inches (44.45mm). A typical switch or patch panel is 1U, a rack UPS 2U, and a server 1U–2U. A 9U rack holds nine 1U devices.

Step 1: Add Up Your Equipment

List everything going in the rack and its height:

  • Patch panel: 1U each
  • Cable manager: 1U each
  • Switch: 1U each
  • NVR or router on a shelf: usually 1–2U
  • PDU: 1U
  • Rack UPS: 2U or more

Then add 30–50% for future growth and airflow.

Step 2: Choose the Depth

Depth Best for
400–450mm Patch panels and small switches in tight spaces
600mm Switches, patch panels, most NVRs
800mm Short servers, rack UPS
1000mm Full-depth rack servers and storage

Always measure your deepest device and allow space at the back for cables.

Step 3: Wall Mount or Floor Standing?

  • Wall mount racks (4U–18U) save floor space and suit shops, small offices and CCTV.
  • Floor standing racks (18U–42U) carry heavier equipment and come with cooling fans and a shelf, for server rooms and data centres.

Typical Sizes by Setup

Setup Suggested rack
Small CCTV or shop network 4U–6U wall rack
Small office (up to ~24 points) 9U–12U wall rack
Medium office (48+ points) 15U–18U
Server room 27U–37U floor rack
Data centre / core network 42U, 1000mm deep

Finish the Rack

Add patch panels, a rack PDU, 1m patch cords and a UPS. See all rack and data room accessories.